GLP and GCLP are often mentioned together, and both are about producing reliable, reconstructable laboratory data. But they apply to different kinds of studies, come from different regulatory frameworks and are overseen in different ways. Getting the distinction right matters, especially for laboratories that do both kinds of work.
The short answer
- GLP (Good Laboratory Practice) applies to non-clinical safety studies, such as toxicology and other preclinical studies, whose results support applications to regulators for medicines, chemicals and other products.
- GCLP (GCP for laboratories) applies to laboratories that analyse or evaluate samples from clinical trials in humans.
If the samples come from trial participants, you are in GCLP territory. If the study is a regulated non-clinical safety study, GLP applies.
Side by side
| GLP | GCLP | |
|---|---|---|
| Study type | Non-clinical safety studies | Clinical trials in humans |
| Typical laboratories | Toxicology, preclinical, contract safety testing | Central, bioanalytical, biomarker, speciality |
| Basis | OECD Principles of GLP, implemented in national law (in the UK, the Good Laboratory Practice Regulations 1999, as amended). In the US, FDA’s 21 CFR Part 58 closely parallels them | Principles of GCP (ICH E6(R3)), interpreted through GCLP guidance and regulator expectations |
| Key roles | Test facility management, study director, independent QA | Laboratory management, the person responsible for the analytical work, independent QA, with sponsor oversight |
| Oversight | National GLP monitoring authority (in the UK, within the MHRA) | GCP inspections of sponsors and laboratories, sponsor audits, optional certification |
| Central document | Study plan and final report | Trial protocol, analytical plan and sponsor agreement |
What they share
The day-to-day expectations overlap heavily, which is why laboratories that understand one usually adapt well to the other:
- an independent quality assurance function
- documented procedures, training and competence
- calibrated, maintained equipment and validated computerised systems (for GLP, OECD GLP Advisory Document No. 17; for clinical work, the EMA guideline on computerised systems and electronic data in clinical trials)
- controlled data, with audit trails and secure archiving (for GLP, see also OECD GLP Advisory Document No. 22 on data integrity)
- the ability to reconstruct exactly what was done, by whom and when
Where they differ in practice
- Participant protection. GCLP adds confidentiality of trial participants and, where applicable, maintaining blinding.
- Sample chain of custody. Clinical samples arrive from many sites, often internationally, so receipt, condition checks and traceability back to the participant visit get particular attention.
- Sponsor relationship. GCLP laboratories work to the sponsor’s protocol and contract, and sponsors are accountable for overseeing them. Expect sponsor audits.
- Formal status. GLP test facilities are enrolled in a national compliance monitoring programme. GCLP has no equivalent statutory programme, which is why some laboratories pursue independent certification to demonstrate conformance.
Laboratories doing both
Many contract laboratories support both non-clinical and clinical work. A single quality system can serve both, provided it is clear which expectations apply to which studies, roles are defined for each framework, and records show the right standard was followed. Computerised systems and data integrity controls are usually shared, so getting them right benefits both.
How we can help
We support GLP laboratories with independent gap analysis, facility audits and inspection readiness, and GCLP laboratories with conformance assessments, certification readiness and sponsor audit preparation. For laboratories working across both, we can review where a shared quality system needs framework-specific controls.