Laboratories that analyse or evaluate samples from clinical trials sit between two worlds. Their work generates data that supports decisions about trial participants and, ultimately, regulatory submissions, so it needs to meet the principles of Good Clinical Practice (GCP). But GCP guidance is written mainly for sponsors, investigators and trial sites, not for laboratory operations.
Good Clinical Laboratory Practice (GCLP), often described as GCP for laboratories, fills that gap. It brings the laboratory controls familiar from Good Laboratory Practice (GLP) together with the objectives of GCP. This guide explains what it covers, where the expectations come from and how to prepare.
Which laboratories does GCLP apply to?
GCLP is relevant to any laboratory that analyses or evaluates samples collected as part of a clinical trial, including:
- central laboratories providing safety testing across multi-site trials
- bioanalytical laboratories measuring drug concentrations (pharmacokinetics)
- biomarker, immunology, genomics and other speciality laboratories
- hospital or academic laboratories supporting investigator-led or sponsor trials
It applies whether the laboratory is part of the sponsor’s own organisation or a contracted service provider.
Where do GCLP expectations come from?
There is no single GCLP regulation. The expectations come from the principles of GCP applied to laboratory work, and from guidance that interprets them:
- GCP itself (ICH E6(R3)) sets the overarching principles: protecting participants and producing reliable, credible trial data. The R3 revision, adopted by ICH in January 2025, has a stronger focus on data governance and computerised systems, which applies directly to laboratory systems.
- Published GCLP guidelines, first produced by the UK quality assurance community (BARQA, now the Research Quality Association) in 2003 and later adapted by the World Health Organization’s TDR programme (2009), describe what those principles mean in a laboratory.
- The EMA reflection paper for laboratories that perform the analysis or evaluation of clinical trial samples (EMA/INS/GCP/532137/2010, adopted by the EMA GCP Inspectors Working Group in February 2012) sets out what European GCP inspectors expect.
- The EMA guideline on computerised systems and electronic data in clinical trials (2023) covers the systems and data that laboratories generate for trials.
In practice, sponsors and CROs translate these into their own expectations of the laboratories they contract, and some laboratories choose to demonstrate conformance through formal certification.
What does GCLP cover in practice?
The themes will be familiar to anyone who has worked to GLP or GMP, applied to the clinical trial context:
- Organisation and personnel: clear responsibilities, training records and documented competence.
- Quality system: procedures, document control, deviations, CAPA, change control and independent quality assurance.
- Protocol and contract alignment: analytical work plans that reflect the trial protocol and sponsor agreements.
- Sample management: receipt, chain of custody, storage conditions, retention and disposal.
- Method validation and analysis: validated methods (for bioanalysis, ICH M10 Bioanalytical Method Validation and Study Sample Analysis), acceptance criteria and controlled reanalysis.
- Equipment and computerised systems: calibrated and maintained instruments, and validated systems such as LIMS and instrument software.
- Data integrity: ALCOA++ principles, audit trails and their review, and secure archiving.
- Reporting and confidentiality: accurate results reported to sponsors, protecting participant identity and blinding where required.
Common gaps
The issues that come up most often in GCLP audits are rarely exotic. They tend to be:
- computerised systems in use without proportionate validation, especially spreadsheets and instrument software
- audit trails that exist but are never reviewed
- sample chain of custody that cannot be fully reconstructed
- deviations recorded without root cause analysis or effective CAPA
- quality assurance that is not independent of the work it reviews
Preparing for a sponsor audit, inspection or certification
A practical sequence works for most laboratories:
- Gap assessment. Review your quality system, processes, computerised systems and data integrity controls against GCLP expectations, and rank findings by risk.
- Prioritised remediation. Address critical gaps first, particularly anything affecting data reliability or participant confidentiality.
- Evidence. Make sure what you do is documented and retrievable: procedures, training, validation and review records.
- Independent review. An objective check before the real audit shows whether the changes have worked.
How we can help
We provide independent GCLP gap assessments, laboratory audits and certification readiness support for clinical laboratories, and help sponsors and CROs oversee the laboratories they contract. Because laboratory compliance depends heavily on systems and data, our reviews cover computerised systems and data integrity alongside laboratory processes.